Various noise removal design configurations | SNR of the modified reconstruction signal (dB) | ΔSNR (dB) |
256 points Hanning window One-half overlapped data buffers 3 frames averaging | 12.4914 | −0.5334 |
256 points Hanning window One-half overlapped data buffers 6 frames averaging | 12.4538 | −0.5710 |
256 points Hanning window One-fourth overlapped data buffers No frame averaging | 13.3619 | 0.3371 |
256 points Hanning window One-fourth overlapped data buffers 3 frames averaging | 12.3457 | −0.6791 |
256 points Hanning window One-fourth overlapped data buffers 6 frames averaging | 12.6906 | −0.3342 |